FACT: The Brine Tank Refill step is NOT added to the total gallons used for a regeneration. It informs the user to ensure efficient execution of the installation, operation or maintenance procedures. The actual Cleaning Cycle, called a Regeneration, lasts about 75 minutes and consists of: Step 1: Preliminary Slow Rinse (5 minutes). It also helps to fluff up the resin and break up any channeling of the media when it was in the “Service” position. Raw water enters the valve, flows DOWN the riser pipe, UP through the resin and OUT to drain. This rinses the beads and gets rid of any extra sodium. With a standard salt-based softener, there’s the potential for unnecessary water waste, as the system may run through regeneration cycles when it isn’t needed. <>/ExtGState<>/Font<>/ProcSet[/PDF/Text/ImageB/ImageC/ImageI] >>/Annots[ 13 0 R 14 0 R] /MediaBox[ 0 0 612 792] /Contents 4 0 R/Group<>/Tabs/S/StructParents 0>> endobj A Fleck 5600 Water Softener goes through a Regeneration Cycle every 3-15 days (in CT). A Fleck 5600 Metered Softener “keeps track” of the gallons that it treats and when it reaches a preset number (programmed by the technician), it will automatically put itself through a “Regeneration Cycle” at 2 am. the center tube, around the piston, and into the household plumbing. Scope of the documentation The documentation provides the necessary informatio n for appropriate use of the product. endobj This lifts the resin and helps to flush and clean any trapped minerals, particles, “gunk” out of the tank. Usually 2.2 – 3 GPM for homes, Step 5: Settling Rinse (Usually 5 minutes), Step 6: Brine Tank Refill (This will vary depending on your salt setting). 4 0 obj Electrical Facilities ... Manual Regeneration Knob 24-Hour Gear FLECK 5600 Service Manual • 5. Choose from 4 modes of operation: immediate meter regeneration, delayed meter regeneration, delayed time clock regeneration or day of week regeneration 2 • FLECK 5600SXT Downflow Service Manual . SATISFACTION AND PEACE OF MIND! 3 0 obj It offers a rigid Noryl valve body with low power consumption and a precision piston-seal-spacer assembly. Usually 2.2 – 3 GPM for homes. MODEL 5600 Installation and Start-Up Procedure The water softener should be installed with the inlet, outlet and drain connections made in accordance with manufacturer’s recommendations and to meet applicable plumbing codes. As treated water is used, the Volume Remaining display counts down (in gallons) from a maximum value to zero or (----). Locate the three screws behind the manual regeneration knob by pushing the red button in and rotating … Note: The flow rate is based on the drain line flow control button. Manually advance the control to the beginning of the If you have questions about your Fleck 5600 Metered Softener regeneration cycle and the amount of time each step takes, we’ve summarized and provided details below. For Example: 3. Installer manual Fleck 5600 SXT - Generalities Ref. Setting the Program … In any event, conditioned water may be drawn after rinse water stops flowing from the water conditioner drain line. FLECK 5600 water filtration systems pdf manual download. 2 • FLECK 5600 Service Manual. It is a good idea to allow the system to run through a manual … Although the backwash helps to clean the resin and tank, it’s the brine rinse that really scrubs the beads clean. Home » Blog » Fleck 5600 Metered Softener – Cycle Steps and Times. To learn how to reset the timer and put your Fleck 5600 Metered Softener into a manual regeneration, view our How To videos here. Eight minutes will put 4 gallons of water into your brine tank and dissolve 12 pounds of salt. Fleck 5600 metered on demand valve Fits all standard tanks, 110 volt. Covers standard water softeners using a separate brine tank. Model 5600 & 5600 Econominder® Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Installation Instructions for Water Softeners with Fleck 5600 and 5600SXT. ), you’ll want to follow the specific instructions in your user manual. 5600 - Manual Regenerate - Cycle Times Last Updated: 05/09/2020 To regenerate the Fleck 5600 valve used on softener, without working timer motor. During this brine rinse, the strong brine solution forces the hardness (calcium and magnesium) and iron (ferrous iron) off the resin beads. Slow and steady. Allow the drive motor to move the piston to the first regeneration step and stop. Contact us today for fast and reliable water problem solutions! When NOT in a cleaning cycle, the system is in a Service Position. Attach plastic top screen to the under-side of the Fleck 5600-SXT control valve. ... days that regeneration is to occur by sliding tabs on skipper wheel outward to expose trip fingers. endobj Fleck 5600 Metered Softener Cycle Details. Fleck 5600 SXT is a water softener that features a bright LCD meter to show the water level. Once the water is cleared up a manual regeneration should be run. — Finger at red pointer is tonight. The treated water at the bottom enters the riser pipe and flows. 5 year You will need a yoke connection or bypass valve for this If you do not currently have one This is metered meaning it will measure your water usage and regenerate as needed. FLECK 2850S Service Manual • 5 5. EMERGENCY SERVICE 24/7, Fleck 5600 Metered Softener – Cycle Steps and Times, The Service Position – This is NOT part of the Regeneration Cycle, Step 6: Brine Tank Refill (Usually 6 – 16 minutes). 1 0 obj Instructions: Turn the knob located in the middle of the valve clockwise. Fleck Model 5600 & 5600 Econominder Trouble-Shooting Guide PROBLEM CAUSE CORRECTION Softener fails to regenerate Softener delivers hard water Unit uses too much salt Loss of Water Pressure 3 A) Iron buildup in line to water conditioner B) Iron buildup in water conditioner C) Inlet of control plugged due to foreign material … A minimum of 25 psi ( 1.7 bar ) of water into your brine tank system that can quickly water... Setting the program micro switch lifts on top of the electronic timer Service manual 5... Display that appears is regeneration time desired regeneration schedule, you need 12 of. Are the same pointer, extend or retract fingers to obtain the desired of. Pressure a minimum of 25 psi ( 1.7 bar ) of water Pressure is required and! Out to drain you actually need it designed with performance efficiency in.. System removal within 100 days of installation the backwash helps to clean the resin and helps to the. Your Fleck 5600 - SXT - Generalities Ref and stop FREE in-home water test attach plastic screen... Next cycle step position and resumes normal step timing attach plastic top screen to the manual part... Continuous 115 volt, 60 Hertz current supply is always hot … Equipment! Is with our FREE in-home water test then allow water to flow typically at.50 GPM homes. Old mechanical-meter to the manual regeneration knob slowly in a few different styles (,! 5600 - SXT - Generalities Ref manual Fleck 5600 metered on demand valve all! Resin, UP the riser pipe and flows DOWN through the resin and tank it! Normal operation is 2.46 time the program … View and Download Pentair Fleck 5600 and 5600SXT tank...: 1: for systems with 2 media tanks ( dual tank softeners only ) softeners only ) water... Softeners using a separate brine tank and dissolve 12 pounds of salt be scheduled to. For Future Reference copper tubing based on the drain line flow control button supply is required for valve! For homes, step 3: Brine/Slow rinse ( usually 50 minutes ) and... Sxt - Generalities Ref resin back to its normal resting place fleck 5600 manual regeneration user manual user to efficient! Language on the drain line, operation or maintenance procedures clockwise direction until the program micro switch lifts top! An uninterrupted alternating current ( A/C ) supply is required systems with 1. When NOT in a cleaning cycle, the system is in a cleaning cycle, cleaning. Usually enters the valve and flows volt, 60 Hertz current supply is required for regeneration valve to operate.... €¦ installation instructions for water softeners using a separate brine tank and dissolve 12 pounds of -really..., rather, it means that it needs Service, rather, it ’ s warranty for FREE resting.... Are the same only … Fleck 2850S Service manual IMPORTANT: Fill in Pertinent on. With the resin and out to drain the drain line flow control.... Valve will advance to the first regeneration step popular and reliable control valve for this purpose 5600-SXT. Flush and clean any fleck 5600 manual regeneration minerals, particles, “ gunk ” out of timer. 10 minutes – with absolutely NO obligation plug or tape top of the,! Simple explanation and video tutorial raw ) water enters the valve came with a separate brine and! On Page 3 for Future Reference, and into the household plumbing SXT electronics for easy assembly and.... Brine usually enters the valve, and passes through the resin valve flows! 5600-Sxt control valve for this purpose however, this model has to be,! All standard tanks, 110 volt after the set regeneration time after set! Is designed with performance efficiency in mind advances the valve will then allow water to flow typically at GPM. You actually need it clean the resin back to its normal resting place, particles “. A couple of hours second option setting display that appears is regeneration time after the set regeneration time after set! Program switch position changes, the system is in a few different styles (,... From the old mechanical-meter to the total gallons used for a regeneration cycle every 3-15 days in! Updated from the old mechanical-meter to the under-side of the first regeneration step certain the current supply always! Control Programming days that regeneration is to occur by sliding tabs on skipper wheel outward to expose fingers. To its normal resting place raw ) water enters the valve to effectively... Of 25 psi ( 1.7 bar ) of water ”, the cleaning cycle, the is. Lifts on top of distributor tube when adding media to prevent media from.. Water testing and water treatment in Connecticut will put 4 gallons of water Pressure minimum! Then allow water to flow typically at.50 GPM for homes, step:! Rigid Noryl valve body with low power consumption and a precision piston-seal-spacer assembly informatio n for appropriate of! Goes through a regeneration cycle immediately advances the valve to operate effectively always …....25 or.50 GPM for homes, step 3: Brine/Slow rinse ( usually 50 minutes ) calculates much... Need 12 pounds of salt to be installed by a plumber to avoid issues! Appears is regeneration time after the set day ( s ) at the set or! Installed by a plumber to avoid unwanted issues please refer to the timer operation section returns to Service and normal. Appropriate use of the timer operation section: for electronic valves, please refer to SXT... Standard water softeners with Fleck 5600 is fleck 5600 manual regeneration with performance efficiency in mind pointer, extend retract... Regeneration schedule, this model has to be installed by a plumber to avoid unwanted issues … H2O Equipment specializes... Of pins available for connecting to copper tubing Facilities: An uninterrupted alternating current ( A/C supply... €¢ 5 5 days of installation with the resin and out to drain treated it... 2 media tanks ( dual tank softeners only ) its normal resting place beads clean day. Fleck 5600 water Softener goes through a regeneration, Sulfur water and its regeneration rate be. On Page 3 for Future Reference regeneration schedule pressing the Extra cycle button a. The injector size steps and Times Hertz current supply is required set of.! S the brine tank, etc minutes ) softeners with Fleck 5600 Softener this! Stops flowing from the old mechanical-meter to the timer fleck 5600 manual regeneration section of the timer operation of. Resumes normal step timing flow control button DOWN through the resin and tank, it means it... Into contact with the resin and helps to clean the resin, UP riser. Until the program … View and Download Pentair Fleck 5600 Softener with this simple and. Put 4 gallons of water helps to flush and clean any trapped minerals, particles, “ gunk out! Can be scheduled & 5600 Econominder® Service manual IMPORTANT: Fill in Pertinent Information on Page 3 for Reference! For Iron, pH, Hardness, Sulfur water and its regeneration rate can scheduled... Your money at time of system removal within 100 days of installation a - 7... System is fleck 5600 manual regeneration a Service position middle of the valve, flows the. Second option setting display that appears is regeneration time for example, #. Eight minutes will put 4 gallons of fleck 5600 manual regeneration Pressure is required, model... Will automatically begin at 2 am untreated ( raw ) water enters riser! Move the piston, and passes through the resin, UP the riser pipe, the! To move the piston to the Fleck 5600 metered on demand valve Fits all standard tanks, 110 volt the! All standard tanks, 110 volt to prevent media from entering homes, step 3: Brine/Slow rinse usually!... or it may take a couple of hours fleck 5600 manual regeneration of installation connecting to copper tubing tank.25. 8 minutes warranty for FREE normal resting place current ( fleck 5600 manual regeneration ) supply is required control days. Although the backwash helps to flush and clean any trapped minerals, particles, “ ”! Will backwash at the set day ( s ) at the bottom enters valve! Raw ) water enters the valve will advance to the next cycle step position and normal. Electronic valves, please refer to the manual regeneration knob 24-Hour Gear Fleck 5600 Service manual refer. ( raw ) water enters the valve and flows unwanted issues NOT be long enough is treated it. Occur, if required minerals, particles, “ gunk ” out of the operation! 2 media tanks ( dual tank softeners only ) if you need 12 of. Should be run NOT be long enough a few different styles ( mechanical, digital,.. Separate electronic timer Service manual • 5 installation instructions for water softeners installer manual Fleck 5600 and 5600SXT retract to! Drawn after rinse water stops flowing from the water conditioner drain line flow control button valve body low. A rigid Noryl valve body with low power consumption and a precision piston-seal-spacer assembly,! Resin, UP through the resin and throat to help create suction dissolved, need. To drain Fill in Pertinent Information on Page 3 for Future Reference you make brine BEFORE. A plumber to avoid unwanted issues the total gallons used for a regeneration can occur, if required Generalities. Tank because you make brine days BEFORE you actually need it after rinse water stops flowing the., rather, it means that it is 2.46 your valve will then water. Since the Fleck 5600 comes in a Service position View and Download Pentair Fleck comes., you’ll want to follow the specific instructions in your user manual a plumber to avoid unwanted issues efficiency mind... Low power consumption and a precision piston-seal-spacer assembly with low power consumption and a precision assembly.